7001490 Centrifuges
COMMON FEATURES
7" TFT touch screen.
Furniture: aluminum structure in Megafriger model and in steel tube with Dur-Al si- des in Macrofriger model.
InternalStainless steel bowl .
Aluminium windbreak cover.
Safety shield: 8 mm thick steel.
Swing-out rotor, buckets and adapters made of high-density material, engraved identification unalterable.
Suspended motor with silent-block and shock absorbers that guarantee smooth, quiet operation without vibrations.
Drive force: equipped with an induction drive maintenance free and highly efficient pollution free motor.
Semi-hermetically sealed, compressorpollutionfree withnohydrocarbons or fluoro- carbons.
Mounted on an anti vibration adjustable rubber feet.
Microprocessor digital control of all functions: speed, acceleration, brake, R.C.F., temperature, time, 10 program memory, rotor identification, operation fault alarm.
Digital indicator of the rotor and blood bag buckets operating hours.
APPLICATIONS
Speciallydesignedforbloodbankapplications, whererepeatability,precisionandre- liability of: speed, time, temperature, acceleration and deceleration are significant factors in obtaining perfect separations of the distinct blood fractions.
Serology investigatios.
Molecular biology.
Serum separation, pharmaceutical applications.
CONTROL PANEL
Touch screen
1. Stop process key.
2. Start process key.
3. Increase value key.
4. Decrease value key.
5. Scheduled acceleration ramp.
6. Rotor model in use.
7. Reading the real time temperature. (refrigerated models only).
8. Door opening key.
9. RPM or RCF real-time reading.
10. Sequential operation.
11. Time set-up in process.
12. Key to change RPM / RCF.
13. Braking ramp programmed.
14. Return key..
TECHNICAL SPECIFICATION
Maximum volume: . . . . . . . . . . . . . . . . . . . . . . . . .9600 ml
Maximum bucket volume: . . . . . . . . . . . . . . . . . . . .1600 ml
Speed 7001490.: . . . . . . . . . . . . . . . . . . . . . . . . . .from 300 to 4070 r.p.m.
Accuracy: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .± 5 r.p.m.
Resolution r.p.m: . . . . . . . . . . . . . . . . . . . . . . . . . .10 r.p.m.
R.C.F.: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .from 29 to 5430
Imbalance: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .± 5 g
Accuracy: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4 g
Temperature range: . . . . . . . . . . . . . . . . . . . . . . . .from -20 degree to 40 degree
Temperature stability: . . . . . . . . . . . . . . . . . . . . . . .±4 degree
Resolution: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1 degree
Temperature range: . . . . . . . . . . . . . . . . . . . . . . . .99 min. 59 sec.
Centrifuge radius: . . . . . . . . . . . . . . . . . . . . . . . . . .290 mm
Acceleration profile: . . . . . . . . . . . . . . . . . . . . . . . .5
Brake profile: . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9 linear 6 quadratic
Voltage: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .230/400 three phase.
Power: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4500 VA
Max. Capacity: . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 bags x800 ml
Height / Width / Depth (exterior) cm: . . . . . . . . . 105 96 96
Weight Kg: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .420